From b67f1b28726b40eafb2bd2818040dfac7626c9aa Mon Sep 17 00:00:00 2001 From: Szymon Dziok Date: Sun, 4 Mar 2012 21:05:58 +0100 Subject: HDD6330: Correct voltage values, based on the values found in the OF. Change-Id: I76a101cd2c96be06fc95ca16871e5c86c2326c2d --- firmware/target/arm/philips/hdd6330/powermgmt-hdd6330.c | 8 ++++---- 1 file changed, 4 insertions(+), 4 deletions(-) diff --git a/firmware/target/arm/philips/hdd6330/powermgmt-hdd6330.c b/firmware/target/arm/philips/hdd6330/powermgmt-hdd6330.c index 938d8ce14c..0f5dc4f4f7 100644 --- a/firmware/target/arm/philips/hdd6330/powermgmt-hdd6330.c +++ b/firmware/target/arm/philips/hdd6330/powermgmt-hdd6330.c @@ -26,25 +26,25 @@ const unsigned short battery_level_dangerous[BATTERY_TYPES_COUNT] = { - 3550 + 3500 }; const unsigned short battery_level_shutoff[BATTERY_TYPES_COUNT] = { - 3500 + 3400 }; /* voltages (millivolt) of 0%, 10%, ... 100% when charging disabled */ const unsigned short percent_to_volt_discharge[BATTERY_TYPES_COUNT][11] = { - { 3480, 3550, 3590, 3610, 3630, 3650, 3700, 3760, 3800, 3910, 3990 }, + { 3400, 3550, 3630, 3690 ,3730, 3770, 3810, 3850, 3890, 3930, 3980 }, }; #if CONFIG_CHARGING /* voltages (millivolt) of 0%, 10%, ... 100% when charging enabled */ const unsigned short percent_to_volt_charge[11] = { - 3480, 3550, 3590, 3610, 3630, 3650, 3700, 3760, 3800, 3910, 3990 + 3400, 3550, 3630, 3690 ,3730, 3770, 3810, 3850, 3890, 3930, 3980 }; #endif /* CONFIG_CHARGING */ -- cgit